Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Artigo em Inglês | LILACS, BBO | ID: biblio-1056840

RESUMO

Abstract Objective: To evaluate the sealing capacity and retention of apical barriers made with mineral trioxide aggregate (MTA) and Portland cement (PC). Material and Methods: Fifty-six bovine incisors were sectioned 8 mm above and 12 mm below the cement-enamel junction. The root canal was enlarged with a diamond drill to create a standard 2.5 mm diameter opening. Apical sheets of 5 mm thickness were placed using white MTA-Angelus or white PC. Fifteen samples of each material were exposed to human saliva in a dual chamber apparatus and casting was evaluated at 30 days. Samples without apical barriers and fully sealed samples were used as positive and negative controls (n = 3), respectively. Data were analyzed by Fisher's exact test (p<0.05) after 3 periods: 1 to 10 days (P1); days 11 to 20 (P2); and days 21 to 30 (P3). Then, three 1 mm thick sections were obtained at the apical level of other root samples of each material (n = 10) and the push-out test was performed Results: The leakage rates in P1, P2 and P3 were 60%, 73.3% and 100% for the MTA; and 73.3%, 86.7% and 100% for CP, with no significant difference between materials, regardless of the period analyzed. There were no significant differences between the bond strengths for both cements (p>0.05) Conclusion: Mineral trioxide aggregate and Portland cement apical barriers presented similar sealing ability and bond strength values.


Assuntos
Animais , Bovinos , Tratamento do Canal Radicular/instrumentação , Traumatismos Dentários/diagnóstico por imagem , Dentição Permanente , Cavidade Pulpar , Apexificação/instrumentação , Brasil/epidemiologia , Radiografia Dentária/instrumentação , Interpretação Estatística de Dados , Esmalte Dentário
2.
Braz. dent. j ; 26(1): 79-85, Jan-Feb/2015. graf
Artigo em Inglês | LILACS | ID: lil-735842

RESUMO

This paper describes two cases of instrument fragment removal from the apical thirds of root canals using a customized extractor and a modified needle technique, respectively. In case 1, a customized extractor was manufactured to remove a bur fragment located in the apical root canal of a maxillary central incisor. The use of this extractor enabled successful and conservative removal of the instrument fragment. In case 2, a modified injection needle was used as a trepan to gain access around an instrument fragment located in the curved apical portion of the mesiobuccal canal of a mandibular molar. A segment of steel wire was inserted into the needle lumen to engage the metallic fragment, enabling its removal with counter-clockwise rotation and a simultaneous pull-out motion. Alternative and creative methods are useful for the management of intracanal metallic fragments during root canal treatment.


Este relato descreve dois casos de remoção de fragmentos de instrumentos de terços apicais de canais radiculares utilizando um extrator personalizado e técnica da agulha modificada, respectivamente. No Caso 1, um extrator foi fabricado para remover fragmento de broca localizado no terço apical do canal radicular de um incisivo central superior. O uso deste extrator permitiu a remoção bem sucedida e conservadora do fragmento de instrumento. No Caso 2, uma agulha para anestesia modificada foi utilizada como um trépano para ganhar acesso ao redor de um fragmento de instrumento localizado na porção apical curva do canal mésio-vestibular de um molar inferior. Um segmento de fio de aço foi inserido no lúmen da agulha para envolver o fragmento metálico, permitindo sua remoção com rotação no sentido anti-horário e simultâneo movimento de retração. Métodos alternativos e criativos são úteis para a remoção intracanal de fragmentos metálicos durante o tratamento endodôntico.


Assuntos
Humanos , Feminino , Criança , Pessoa de Meia-Idade , Corpos Estranhos/terapia , Tratamento do Canal Radicular/instrumentação , Brasil , Instrumentos Odontológicos , Desenho de Equipamento , Falha de Equipamento , Incisivo , Dente Molar , Agulhas
3.
Braz. dent. j ; 25(6): 571-575, Nov-Dec/2014. graf
Artigo em Inglês | LILACS | ID: lil-732261

RESUMO

This case report describes root canal filling performed over a large S1 ProTaper file fragment in a second mandibular molar with irreversible pulpitis. An S1 ProTaper file was fractured during the instrumentation of the mesiobuccal canal. Approximately 10 mm of file fragment remained in the apical and middle thirds of the canal. The obturation was performed over this fragment using thermomechanically compacted gutta-percha and sealer. Radiographic findings and the absence of clinical signs and symptoms at 3-year follow up indicated successful treatment. Cone-beam computed tomography images revealed absence of periapical lesion and details of intracanal file fragment related to root fillings and apex morphology. In this case, the presence of a large intracanal fractured instrument did not have a negative impact on the endodontic prognosis during the follow up evaluation period.


Este relato de caso descreve a obturação do canal radicular realizada sobre um grande fragmento da lima ProTaper S1 em um segundo molar inferior com pulpite irreversível. Uma lima ProTaper S1 fraturou durante a instrumentação do canal mésio-vestibular. Aproximadamente 10 mm de remanescente do fragmento da lima permaneceu nos terços apical e médio do canal. A obturação foi realizada sobre este fragmento usando guta-percha compactada termomecanicamente e cimento endodôntico. Achados radiográficos e ausência de sinais e sintomas clínicos após 3 anos de acompanhamento indicaram o sucesso do tratamento. Imagens de tomografia computadorizada de feixes cônicos revelaram a ausência de lesão periapical e detalhes do fragmento da lima intracanal relacionados à obturação do canal radicular e à morfologia do ápice. Neste caso, a presença de grande instrumento fraturado intracanal não teve impacto negativo no prognóstico endodôntico durante o período de acompanhamento.


Assuntos
Técnicas Bacteriológicas , Campylobacter/ultraestrutura , Centrifugação com Gradiente de Concentração , Membrana Celular/análise , Membrana Celular/efeitos dos fármacos , Eletroforese em Gel de Poliacrilamida , Ácido Edético/farmacologia , Octoxinol , Polietilenoglicóis/farmacologia , Sarcosina/análogos & derivados , Sarcosina/farmacologia
4.
J. appl. oral sci ; 22(2): 98-102, Mar-Apr/2014. graf
Artigo em Inglês | LILACS, BBO | ID: lil-704192

RESUMO

Objective: This study evaluated apical transportation associated with ProTaper® Universal Fl, F2 and F3 rotary files in curved canais prepared by undergraduate students. Material and Methods: Twenty mesial roots of mandibular molars with curvatures ranging between 25° and 35° were selected. Mesiobuccal canals were instrumented by twenty students with the ProTaper® system (Dentsply-Maillefer, Ballaigues, Switzerland) according to the manufacturer's instructions. Pre-fiaring was performed with Sl and SX files. A #15 K-file was inserted into the root canal up to the working length (WL), and an initial digital radiograph was taken in a buccolingual direction (baseline). Afterwards, the S1, S2, F1, F2, and F3 files were employed up to the WL. Other radiographies were taken in the same orientation of the baseline after the use of the Fl, F2, and F3 files, with each file inserted into the root canal. The radiographic images were overlapped, and the Image J software was used to measure the distance between the rotary files' ends and the #15 K-file's end, characterizing the apical transportation. Data were analyzed by Repeated Measure ANOVA and by the SNK post hoc test (P<0.05). Results: It was verified that file size affected apical transportation significantly (P<0.001). The F3 file showed higher apical transportation than Fl and F2, while between these last files there was no difference. Conclusion: The undergraduate students produced lower apical transportation in curved canals when they did not use the F3 rotary file. .


Assuntos
Humanos , Instrumentos Odontológicos , Cavidade Pulpar/anatomia & histologia , Preparo de Canal Radicular/instrumentação , Estudantes de Odontologia , Ápice Dentário/anatomia & histologia , Análise de Variância , Cavidade Pulpar , Desenho de Equipamento , Teste de Materiais , Níquel , Odontometria , Reprodutibilidade dos Testes , Preparo de Canal Radicular/métodos , Titânio , Ápice Dentário
5.
Braz. dent. j ; 24(6): 575-579, Nov-Dec/2013. graf
Artigo em Inglês | LILACS | ID: lil-697655

RESUMO

Maxillary molars present variable root canal and root morphologies. This report describes the endodontic management of two cases of midbuccal canals found in maxillary molars. Midbuccal canals were present in a maxillary first molar with a single buccal root (Case 1), and in a maxillary second molar with three buccal roots (Case 2). An assessment of the internal configuration of these teeth was performed using cone-beam computed tomography (CBCT). Magnification with a dental operating microscope, surgical loupes, and the use of an endodontic explorer enabled the identification of the midbuccal canal orifices. The root canals in both cases were chemomechanically prepared and filled. Postobturation radiographic images revealed four (one midbuccal, two mesiobuccal and one palatal) and five (one midbuccal, two mesiobuccal, one distobuccal and one palatal) root canals, which were filled in Cases 1 and 2, respectively. Complex canal configurations of maxillary molars including the presence of midbuccal canals were presented. CBCT was a valuable tool in this diagnosis, as it provided a precise description of these unusual anatomical variations.


Molares superiores apresentam morfologias radiculares e canais radiculares variáveis. Este relato de caso descreve o manejo endodôntico de dois casos de canais mésio-centrais (MC) encontrados em molares superiores. Canais MC estavam presente em um primeiro molar superior com uma única raiz vestibular (Caso 1), e em um segundo molar com três raízes vestibulares (Caso 2). Uma avaliação da configuração interna destes dentes foi realizada usando tomografia computadorizada de feixe cônico (TCFC). Ampliação com microscópio operatório odontológico, lupas cirúrgicas e o uso de um explorador endodôntico possibilitaram a identificação dos orifícios dos canais MC. Os canais radiculares dos dois casos foram preparados e obturados. Imagens radiográficas pós-obturação revelaram quatro (um MC, dois mésio-vestibulares e um palatino) e cinco (um MC, dois mésio-vestibulares, um disto-palatino e um palatino) canais radiculares, que foram obturados nos Casos 1 e 2, respectivamente. Configurações complexas de canais em molares superiores, incluindo a presença de canais MC foram apresentadas. TCFC foi uma ferramenta útil no diagnóstico e propiciou uma descrição precisa destas variações anatômicas incomuns.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada de Feixe Cônico , Dente Molar , Dente Molar/cirurgia , Pulpite , Pulpite/cirurgia , Tratamento do Canal Radicular , Maxila
6.
RGO (Porto Alegre) ; 61(supl.1): 447-452, jul.-dez. 2013.
Artigo em Português | LILACS-Express | LILACS | ID: lil-702842

RESUMO

As perfurações radiculares rompem a barreira biológica entre o endodonto e o espaço periodontal, podendo, em razão da sua extensão e localização, comprometerem, irreversivelmente, a longevidade do elemento dentário. Do ponto de vista terapêutico, o agregado de trióxido mineral é o material selador mais recomendado. O agregado de trióxido mineral é apresentado sob a forma de um pó branco ou cinza, contendo partículas hidrofílicas, cujos componentes principais são silicato tricálcico, aluminato tricálcico, óxido tricálcico, óxido silicato e o óxido de bismuto, responsável pela radiopacidade, além dos elementos cromo e chumbo. Quando incorporado à água destilada, resulta em um gel coloidal que é aplicado diretamente no sítio da perfuração. Seu tempo de presa final é de aproximadamente 3 horas. Esse agregado apresenta satisfatórias propriedades físicas e químicas, bem como compatibilidade com os tecidos perirradiculares, independentemente da sua cor. In vitro, o agregado de trióxido mineral apresenta capacidade de selamento superior a outros biomateriais. No entanto, a maioria das investigações clínicas envolve relatos isolados de casos, com poucas evidências longitudinais dos resultados alcançados.


The alterations provoked by pathologies or iatrogenesis favor the invasion of the periodontium, communicating pulp cavity with periradiculares tissues. Currently, for the treatments of those root perforations, the sealer material more suitable is the mineral trioxide aggregate, that was reported for the first time in 1993 and introduced commercially in 1998. Mineral trioxide aggregate is presented under the form of a powder white or gray that, once incorporate to the distilled water, has an easy manipulation resulting in a colloidal gel whose final time setting is about 3 hours. That aggregate reaches appropriate physical and chemical properties as well as biocompatibility with the periradiculares tissues. In the current review, the use of mineral trioxide aggregate was approached as sealer material of root perforations in both in vitro and in vivo studies. It was evidenced that mineral trioxide aggregate presents good sealing ability, superior the other materials of larger longevity in the dentistry. However, most of the clinical investigations involve isolated case reports, with few longitudinal evidences of the reached results.

7.
J. appl. oral sci ; 20(5): 538-543, Sept.-Oct. 2012. ilus, graf
Artigo em Inglês | LILACS | ID: lil-654918

RESUMO

OBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or "APEX" signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the preflaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra- and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). RESULTS: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. CONCLUSIONS: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size.


Assuntos
Humanos , Instrumentos Odontológicos , Cavidade Pulpar/anatomia & histologia , Odontometria/instrumentação , Preparo de Canal Radicular/instrumentação , Ápice Dentário/anatomia & histologia , Análise de Variância , Eletrônica Médica/instrumentação , Tamanho do Órgão , Reprodutibilidade dos Testes , Preparo de Canal Radicular/métodos
8.
Arq. odontol ; 47(2): 84-89, 2011. tab
Artigo em Português | LILACS, BBO | ID: lil-620878

RESUMO

Objetivo: Investigou-se a representação brasileira nas publicações dos periódicos Journal of Endodontics (J Endod) e International Endodontic Journal (Int Endod J), bem como o perfil dos estudos brasileiros publicados nos dois periódicos. Materiais e Métodos: Todos os artigos publicados entre janeirode 2008 a dezembro de 2010 nos periódicos J Endod e Int Endod J foram acessados por meio do portal deperiódicos da CAPES. Dois pesquisadores avaliaram os artigos quanto ao delineamento, ao tema abordado e ao país de origem. Os estudos brasileiros foram ainda caracterizados quanto ao Estado e instituição de origem dos autores. Foi realizada uma análise descritiva dos dados empregando-se o programa SPSS 17.0. Resultados: Foram publicados, neste período, 1381 artigos (988 no J Endod; 393 no Int Endod J). O Brasilocupou o 2º lugar na produção de artigos científicos, apresentando 232 publicações (16,7%). A maioria dosestudos que geraram essas publicações foram desenvolvidos a partir de experimentos laboratoriais (82,7%)que abordaram principalmente os temas relacionados aos materiais e instrumentos utilizados na práticaendodôntica (55,9%) e à microbiologia endodôntica (23,8%). A maior parte deles eram provenientes de universidades públicas do Estado de São Paulo. Conclusão: O número de artigos brasileiros publicados nos últimos três anos nos periódicos J Endod e Int Endod J foi expressivo, alcançando o segundo lugar mundial.


Assuntos
Bibliometria/história , Jornalismo em Odontologia/história , Interpretação Estatística de Dados , Publicações Científicas e Técnicas
9.
J. appl. oral sci ; 18(5): 528-532, Sept.-Oct. 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-564190

RESUMO

ABSTRACT OBJECTIVE: The aim of this study was to evaluate the effect of simulated periodontal ligament (SPDL) on custom cast dowel and core removal by ultrasonic vibration. MATERIAL AND METHODS: Thirty-two human maxillary canines were included in resin cylinders with or without SPDL made from polyether impression material. In order to allow tensile testing, the roots included in resin cylinders with SPDL were fixed to cylinders with two stainless steel wires. Post-holes were prepared by standardizing the length at 8 mm and root canal impressions were made with self-cured resin acrylic. Cast dowel and core sets were fabricated and luted with Panavia F resin cement. Half of the samples were submitted to ultrasonic vibration before the tensile test. Data were analyzed statistically by two-way ANOVA and Tukey's post-hoc tests (p<0.05). RESULTS: The ultrasonic vibration reduced the tensile strength of the samples directly included in resin cylinders. There was no difference between the values, whether or not ultrasonic vibration was used, when the PDL was simulated. However, the presence of SPDL affected the tensile strength values even when no ultrasonic vibration was applied. CONCLUSION: Simulation of PDL has an effect on both ultrasonic vibration and tensile testing.


Assuntos
Humanos , Instrumentos Odontológicos , Remoção de Dispositivo/instrumentação , Ligamento Periodontal , Técnica para Retentor Intrarradicular/instrumentação , Análise de Variância , Dente Canino , Teste de Materiais , Cimentos de Resina , Preparo de Canal Radicular , Resistência à Tração , Ultrassom , Vibração
10.
RFO UPF ; 14(2): 117-120, maio-ago. 2009. tab
Artigo em Português | LILACS | ID: lil-527869

RESUMO

O objetivo deste trabalho foi avaliar a prevalência e a etiologia de retratamentos endodônticos realizados por estudantes de graduação. Foram analisados retrospectivamente casos de retratamentos endodônticos feitos na Clínica de Endodontia do curso de Odontologia da Universidade Estadual de Montes Claros - Unimontes- MG, Brasil, no período de 2000 a 2004. As análises foram realizadas por meio de avaliação das radiografias e dos dados presentes nos prontuários dos pacientes. Dados pessoais do paciente e história clínica do dente foram anotados, incluindo o tipo do dente envolvido, o gênero e a idade do paciente. Dos 673 casos avaliados, 52 (7,7%) eram de retratamento endodôntico, predominante em pacientes do gênero feminino (57,6%). O dente mais acometido foi o incisivo central superior (34,6%) e a faixa etária prevalente, de 15 a 35 anos (48,1%). A principal causa relacionada com o insucesso do tratamento endodôntico foi a presença de obturações deficientes (94,2%). A maior parte dos dentes envolvidos estava assintomática (67,3%). Conclui-se que a prevalência de dentes com necessidade de retratamento endodôntico na população estudada foi baixa. A etiologia predominante para os retratamentos foi a obturação deficiente dos canais radiculares em dentes assintomáticos.


The aim of this study was to evaluate the prevalence and the etiology of endodontic re-treatments performed by undergraduate students. Endodontic retreatments accomplished in the Dental School of the State University of Montes Claros – Unimontes - MG, Brazil, between the period of 2000-2004 were retrospectively evaluated.The analyses were made using the radiographies and the information present in the patient’s records.Detailed personal and dental history was obtained from the patient’s records, including the tooth type and patient’s gender and age. From a total of 673 cases requiring endodontic treatment, 52 (7.7%) were submitted to endodontic retreatment, predominantly in female patients (57.6%). The more affected tooth was the uppercentral incisor (34.6%) and the prevalent age group was from 15 to 35 years (48.1%). The main reason for the endodontic failure was the presence of poor coronal restoration (94.2%). The majority of the teeth which needed retreatment was asymptomatic (67.3%). In conclusion, the prevalence of endodontic retreatments in the studied population was low. The predominant etiology was the deficient sealing of root canals in the asymptomatic teeth.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Endodontia , Prevalência , Retratamento
11.
Rev. odonto ciênc ; 24(1): 36-39, jan.-mar. 2009. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: lil-506374

RESUMO

Purpose: To evaluate the extraradicular diffusion of creamy 6 % hydrogen peroxide (HP) associated or not with sodium perborate (SP) at the cervical region of endodontically treated teeth during intracoronal bleaching. Methods: Thirty-two endodontically treated maxillary canines and central incisors were used. The gutta-percha was removed 3 mm below the cement/enamel junction, and the external root surface was covered with cyanoacrylate except for the cervical region. The teeth were randomly allocated to 4 groups: G1: 6 % HP+SP (n=11); G2: 6 % HP (n=11); G3: distilled water (negative control, n=5) and G4: 30 % HP (positive control, n=5). The specimens were immersed in a solution of potassium chromate (yellow), which turns blue in presence of HP. Two calibrated examiners (Kendall coefficient = 0.936) attributed scores according to the solution color (0 - unaltered color, 1 - light blue, and 2 - dark blue). Data were analyzed by Kruskal-Wallis and Mann-Whitney tests (α<0.05). Results: Eighteen percent of the 6 % HP specimens with or without SP showed color alteration. Only G4 had score values statistically higher than the other groups (P=0.004). Conclusion: It can be concluded that 6 % HP cream did not have significant extraradicular diffusion during intracoronal bleaching but it was not 100 % safe.


Objetivo: Avaliar a difusão do peróxido de hidrogênio (PH) 6 % em creme, associado ou não ao perborato de sódio (PS) na região cervical de dentes endodonticamente tratados durante clareamento coronário interno. Metodologia: Foram utilizados 32 caninos e incisivos superiores tratados endodonticamente. Removeu-se 3mm de guta-percha abaixo da junção cemento/esmalte e a superfície radicular externa foi impermeabilizada com cianoacrilato, exceto a região cervical. Os dentes foram divididos aleatoriamente em: G1: PH 6 %+PS (n=11); G2: PH 6 % (n=11); G3: águadestilada (controle negativo, n=5) e G4: PH 30 % (controle positivo, n=5). Os espécimes foram imersos em solução de cromato de potássio (cor amarela), que se torna azul na presença do PH. Dois avaliadores calibrados (coeficiente de Kendall = 0,936) atribuíram escores de acordo com a cor da solução evidenciadora (0 - cor inalterada; 1 - azul claro e 2 - azul escuro). Os dados foram analisados pelos testes de Kruskal-Wallis e Mann-Whitney (α=0,05). Resultados: Em 18% dos casos houve difusão extra-radicular do PH 6%, estando este associado ou não ao perborato de sódio. Apenas o G4 apresentou valores estatisticamente maiores que os demais (P=0,004). Conclusão: Pode-se concluir que o PH 6 % em creme não apresentou difusão extra-radicular significativa durante o clareamento coronário interno, mas não foi 100 % seguro.


Assuntos
Humanos , Clareamento Dental , Técnicas In Vitro , Peróxido de Hidrogênio/administração & dosagem , Estudos de Casos e Controles
12.
Braz. oral res ; 23(1): 17-22, 2009. graf, tab
Artigo em Inglês | LILACS | ID: lil-514637

RESUMO

The aim of this in vitro study was to compare the time required for removal of intraradicular cast posts cemented with zinc phosphate (ZF) or glass ionomer cement (GIC), using two Brazilian ultrasound devices (BUD). Seventy two human inferior premolars with single root canals were sectioned transversally at the cementoenamel junction. In each specimen, the root canal was endodontically treated, the post space was prepared to a depth of 9 mm and the canal was molded to obtain a post impression. After the casting procedures, the posts were randomly distributed into 2 groups (n = 36) according to the luting material used: G1 - ZF and G2 - GIC. The tooth and luted post set was then embedded in an acrylic resin block. The groups were then divided into 3 subgroups (n = 12) according to the ultrasound device used: A - Enac (Osada Electric, Japan), used as a control group; B - Profi II Ceramic (Dabi Atlante, Brazil) and C - Jet Sonic Satelec (Gnatus, Brazil). The posts were submitted to the vibration process with maximum power set on all surrounding surfaces. Time of application was recorded with a chronometer until complete post dislodgment, and the data were analyzed by the ANOVA test (p < 0.05). The averages required for post removal in G1 and G2 were respectively 41.42 and 92.03 seconds, with significant statistical difference (p = 0.001). No statistical difference was observed among the three ultrasound devices (p = 0.088), and the BUD presented a performance similar to that of the international gold standard device (Enac). Moreover, the type of luting agent had a greater influence on the time required for post removal than the origin of the ultrasonic unit.


Assuntos
Humanos , Descolagem Dentária/instrumentação , Cimentos de Ionômeros de Vidro , Ultrassom , Cimento de Fosfato de Zinco , Brasil , Fatores de Tempo
13.
Rev. odonto ciênc ; 22(58): 293-298, out.-dez. 2007. ilus, tab
Artigo em Português | LILACS | ID: lil-487207

RESUMO

O presente estudo in vitro teve por objetivo avaliar a precisão e a confibialidade de um modelo de localizador apical eletrônico (LAE) na obtenção do comprimento de trabalho (CT) em molares inferiores. Após adequado acesso endodôntico e manobras iniciais de exploração em 20 dentes, mediu-se com uma lima K # 10 o comprimento dos condutos mésio-vestibular (MV) e distal (D) até o forame apical, subtraindo-se 1 mm (CT1), tendo como referências externas as cúspides mésio-vestibular e disto-vestibular, respectivamente. Os dentes foram fixados em recipientes plásticos contendo alginato procedendo-se as medidas eletrônicas com o LAE Novapex (Fórum,Israel). Limas K # 10 foram inseridas nos canais MV e D até que os instrumentos atingissem a marca 0 no visor do aparelho e posteriormente realizava-se o recuo até a marca 1, ajustando-se os cursores nas mesmas referências externas do CT1. As mensurações com o LAE foram realizadas em triplicata, adotando-se a média das medidas, por dois operadores calibrados, um estudante de gradução (CT2) e um especialista em endodontia (CT3). O coeficiente de correlação linear de Pearson revelou alta concorcândia inter?operadores e intraoperadores. Para comparação do CT1, CT2 e CT3 foi aplicado o Teste t de Student para amostras pareadas (p < 0,05), que não mostrou diferenças significativas entre todas as medidas odontométricas para os canais radiculares MV (p = 0,22 ) e D (p = 0,94). Portanto, o LAE testado mostrou-se preciso e confiável na determinação da odontometria de molares inferiores.


The aim of this in vitro study was to evaluate the accuracy and reliability of an electronic apex locator (EAL) in the determination of the working length (WL) of lower molars. After appropriate endodontic access and exploration in 20 teeth, it was measured with a size 10 K-file the actual canal length (AL) of the mesio-buccal (MB) and distal (D) root canals until the apical foramen. Next, it was subtracted 1mm of the AL (WL1), taking as coronal references the vertex of the mesio-buccal and disto-buccal cusps. The teeth were embedded in an alginate model and electronic tooth length measurements were carried out using the EAL Novapex (Fórum, Israel). A 10 K-type file was inserted down the MB and D canals until EAL indicated that the file had reached the apex retreating until the mark 1. The cursors were adjusted in the same external references of WL1. The eletronic measurements were obtained by two operators, a graduate student (WL2) and a specialist (WL3). Three measurements were taken and an average recorded. The coefficient of Pearson revealed high concordance level inter-operators and intra-operators. For comparison of WL1, WL2 and WL3 the test t of Student was applied (p < 0,05). There was no statistically significant difference between all the measures for MB (p = 0,22) and D (p = 0,94) root canals. Therefore, the tested EAL was accurate and reliable in the determination of the WL of lower molars.


Assuntos
Humanos , Técnicas In Vitro , Odontometria/métodos , Dente Molar
14.
Arq. odontol ; 43(3): 67-72, jul.-set. 2007. ilus
Artigo em Português | LILACS, BBO | ID: lil-533401

RESUMO

Neste estudo in vitro avaliou-se a influência dos desgastes do núcleo e da linha de cimento na remoção ultra-sônica de retentores intra-radiculares metálicos fundidos. Foram utilizados vinte e quatro pré-molares humanos, unirradiculares, que tiveram suas coroas removidas mantendo um remanescente radicular de 15mm. Os canais radiculares foram tratados endodonticamente, sendo preparados espaços para pinos com 9mm de profundidade, que foram moldados para obtenção dos retentores. Após fundição, os pinos foram cimentados com fosfato de zinco (SS White) e o conjunto raiz/pino fixado em tubos de PVC com 0,5 polegada de diâmetro e 3 cm de altura, contendo resina autopolimerizável. Decorridos 7 dias, a amostra foi distribuída aleatoriamente em 2 grupos (n=12): G1- desgastes dos núcleos e linha de cimento + ultra-som, e G2-apenas ultra-som. No G1 realizou-se os desgastes com a broca #1557, circunferencialmente aos núcleos e em seguida na linha cervical do cimento, com uma ponta diamantada cônica #3203 (KG Sorensen), numa profundidade de 2mm. O aparelho Enac (Osada, Japão) em potência máxima, com a ponta ST 09, foi aplicado em todas as faces dos núcleos, registrando-se o tempo até o completo deslocamento dos pinos. Para análise estatística utilizou-se o teste t-Student (p<0,05). Verificou-se que a média de tempo para G1 e G2 foi de 48,4 e 99,4 segundos, respectivamente, com diferença significatica entre os grupos (p=0,036). Portanto, os desgastes do núcleo e da linha de cimento diminuíram, de forma significativa, o tempo de vibração ultra-sônica na remoção de retentores intra-radiculares cimentados com fosfato de zinco.


Assuntos
Técnica para Retentor Intrarradicular , Dente não Vital , Compômeros , Interpretação Estatística de Dados , Pinos Dentários
15.
Arq. odontol ; 43(2): 17-22, 2007. tab
Artigo em Português | LILACS, BBO | ID: lil-518052

RESUMO

Este estudo retrospectivo avaliou a participação de docentes do Curso de Odontologia da Universida de Estadual de Montes Claros, Unimontes, em atividades de pesquisa e extensão nos anos de 2005 e 2006. Os dados foram coletados a partir de documentos gerados pela Diretoria de Recursos Humanos da Unimontes. A análise estatística descritiva e o teste de Likelihood Ratio (p<0,05) foram realizados no programa SPSSri11.0. Participaram 21 docentes, sendo a maioria (61,5 por cento) do gênero feminino, distribuídos nas áreas de Clínicas Integradas (5), Endodontia (3), Estomatologia/Patologia Bucal (3), Odontopediatria (2), Periodontia(2), Prótese (2) e Saúde Coletiva (4). No tocante à atuação simultânea em pesquisa e extensão, nos anos de 2005 e 2006, foi observada participação docente de 33 por cento e 47 por cento respectivamente, sem diferenças significativas (p>0,05) entre os anos. Os professores das disciplinas de Odontopediatria (100 por cento), Saúde Coletiva (75 por cento), Clínicas Integradas (60 por cento) e Endodontia (33 por cento) realizaram ações conjuntas de pesquisa e extensão. Já os docentes de Periodontia, Estomatologia/Patologia Bucal e Prótese não participaram simultaneamente de atividades de pesquisa e extensão, no entanto, todos os professores de Estomatologia/Patologia Bucal atuaram em pesquisa. Foram encontradas diferenças significativas (p<0,05) quando comparadas as disciplinas de atuação dos docentes e práticas de pesquisa e/ou extensão. Concluiu-se que importante parcela do grupo avaliado desempenhou atividades de pesquisa e/ou extensão, mas a prática das ações mencionadas pode ser incrementada.


Assuntos
Docentes de Odontologia/estatística & dados numéricos , Pesquisa em Odontologia/estatística & dados numéricos
16.
Rev. bras. odontol ; 64(3/4): 248-251, 2007. ilus
Artigo em Português | LILACS, BBO | ID: lil-541889

RESUMO

Este relato descreve o sucesso do tratamento endodôntico em dente portador de extensa lesão endo-periodontal combinada, com mobilidade acentuada, e avançada destruição do periodonto de suporte. Após o preparo químico-mecânico auxiliado pela solução de hipoclorito de sódio a 2,5%, o canal radicular foi preenchido com pasta de hidróxido de cálcio e soro fisiológico. A medicação intracanal foi renovada por três vezes, durante 7 meses, período em que ocorreu significativa redução da radiolucidez periodontal, quando se procedeu à obturação do canal radicular. Aos 5 anos, em avaliação clínica e radiográfica, a paciente apresentou-se assintomática, com significativa redução da mobilidade dentária e completo reparo da radiolucidez endo-periodontal.


Assuntos
Humanos , Feminino , Adulto , Perda do Osso Alveolar , Hidróxido de Cálcio/uso terapêutico , Tratamento do Canal Radicular/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA